Why We Built StairStringer
Most online stair and framing calculators either output decimal inches you cannot read on a 25-foot Stanley tape or hide critical checks like perpendicular stringer throat depth and bottom-riser tread deductions. StairStringer was built as a fast, zero-account drafting bench for residential framers, deck builders, and serious homeowners working in imperial US lumber dimensions.
Published Reference Standards
- Stairway geometry & open risers (IRC R311.7): Automatic riser selection caps finished riser height at 7 3/4" (7.75"), flags tread runs under 10", checks perpendicular throat depth against the 3 1/2" structural minimum (and 5" field recommendation), validates IRC R311.7.5.3 tread nosing (3/4"–1 1/4" when tread run is under 11"), and evaluates the IRC R311.7.5.1 open-riser 30" threshold at the actual vertical elevation of the highest riser opening above level grade or landing rather than total deck height alone.
- Actual vs. nominal US lumber sizing: Stringer and rafter depth calculations use dressed US dimensional widths—2×6 (5 1/2"), 2×8 (7 1/4"), 2×10 (9 1/4"), and 2×12 (11 1/4")—while board-foot tallies use standard 144 cubic-inch sawmill quarter notation (4/4 through 12/4).
- Roof framing & birdsmouth cuts (IRC R802.7.1 & R802.7.1.1): Common rafter lengths deduct half the ridge board thickness from the half-span run and compute eave tails along the true slope hypotenuse. Without an eave overhang (0"), end notches are capped at one-fourth (1/4) of actual perpendicular rafter depth (IRC R802.7.1 / R502.8.1). For cantilevered sawn-lumber eaves up to 24", IRC R802.7.1.1 permits full-plate bearing provided at least 3 1/2" of uncut perpendicular rafter depth remains; overhangs over 24" are flagged for structural verification. Whenever a birdsmouth seat must be capped to stay within IRC limits, the executable seat cut is floored down to the nearest 1/16" so tape measurements never round upward past code limits.
- Fractional precision: Internal calculations execute in full IEEE-754 double precision and round at the display boundary to the nearest 1/16" (or floor down to 1/16" on code-capped structural cuts) to prevent cumulative rounding drift across multi-step flights.
Where Calculations Stop
Geometric layout tools cannot inspect your lumber grade, moisture content, soil bearing capacity, frost depth, or regional snow and wind loads. Local city and county amendments frequently override baseline IRC thresholds (for example, 7" maximum risers or mid-span stair blocking over 8 feet). Always confirm structural sizing and hanger hardware with your local building department or licensed engineer before making permanent cuts.