Stair Stringer Calculator & Cut Blueprint

Exact 1/16" rise/run layout, throat depth, and framing square marks checked against US IRC R311.7. 100% Free · Browser-Local · No Sign-up

Presets
Risers & Height
13 × 7 3/8"
7.38" · max 7 3/4"
Treads & Total Run
10' 6"
12 treads @ 10 1/2"
Stringer Board
13' 2 3/8"
Order 4 × 14' 2x12
Throat & Pitch
5 3/16"
35.1° · 2R+T = 25.3"
IRC R311.7 Riser Pass Tread Depth Pass Throat ≥ 5" Solid Width ≥ 36" Pass Handrail Req (≥4 risers)
SIDE ELEVATION · 2X12 (11.25") · DROPPED HANGER MOUNT IRC R311.7 PASS FINISHED LOWER LANDING UPPER FLOOR RIM JOIST THROAT 5 3/16" RISE 96" 13 × 7 3/8" TOTAL RUN 10' 6" (12 treads @ 10 1/2") 35.1° PITCH FRAMING SQUARE SET Rise: 7 3/8" · Run: 10 1/2" Bottom drop cut: 5 7/8"
StairStringer Cut Sheet (2X12 · Dropped Mount)
Total Rise: 96" | Risers: 13 @ 7 3/8" (7.38")
Treads: 12 @ 10 1/2" | Total Run: 10' 6"
Stringer Length: 13' 2 3/8" | Order 4 × 14' 2x12
Throat Depth: 5 3/16" | Pitch: 35.1° | Bottom Riser Drop Cut: 5 7/8"
Framing Square: 7 3/8" Rise × 10 1/2" Run
https://stairstringer.com/

Framing Square Step-by-Step Layout Marks

Use these cumulative tape measurements from the bottom toe of the board to eliminate compounding pencil-width error across long flights. Trim the bottom riser down to 5 7/8" to account for the 1.5" tread board thickness.

Cumulative stringer edge marks along top nosing line (1/16" precision)
Step Cumulative Rise Cumulative Run Diagonal Edge Mark
Step 1 7 3/8" 10 1/2" 12 13/16"
Step 2 14 3/4" 21" 25 11/16"
Step 3 22 1/8" 31 1/2" 38 1/2"
Step 4 29 9/16" 42" 51 3/8"
Step 5 36 15/16" 52 1/2" 64 3/16"
Step 6 44 5/16" 63" 77"
Step 7 51 11/16" 73 1/2" 89 7/8"
Step 8 59 1/16" 84" 102 11/16"
Step 9 66 7/16" 94 1/2" 115 1/2"
Step 10 73 7/8" 105" 128 3/8"
Step 11 81 1/4" 115 1/2" 141 3/16"
Step 12 88 5/8" 126" 154 1/16"

Standard US Residential Stair Stringer Reference Table

Pre-calculated 2×12 dropped-mount layouts for common porch, deck, basement, and two-story floor-to-floor heights using a 10 1/2" tread run.

Worked IRC R311.7 2×12 stringer examples (10 1/2" tread run, dropped mount)
Scenario Total Rise Risers Riser Height Total Run Throat Depth 2×12 Order Stock
Porch 36" 36" 5 7 3/16" 3' 6" 5 5/16" 4 × 8'
Deck 60" 60" 8 7 1/2" 6' 1 1/2" 5 1/8" 4 × 10'
Basement 96" 96" 13 7 3/8" 10' 6" 5 3/16" 4 × 14'
Full Floor 108" 108" 14 7 11/16" 11' 4 1/2" 5 1/16" 4 × 16'
Stair stringer calculator live cut blueprint for a 96-inch basement staircase showing 13 risers at 7 3/8 inches, 12 treads at 10 1/2 inches, 5 3/16-inch throat depth, and 4x14-foot 2x12 lumber takeoff
Example 96" basement stair stringer layout: 13 risers @ 7 3/8", 10' 6" total run, 5 3/16" throat depth, and 4 × 14' 2×12 order stock verified against IRC R311.7.

IRC R311.7 Code Rules, Formulas & Field FAQs

IRC R311.7 Stairway Code Limits & Scope Boundaries

This tool validates layout geometry against the 2021/2024 International Residential Code (IRC) Section R311.7 for one- and two-family US dwellings:

  • Maximum riser height (R311.7.5.1): 7 3/4" (7.75"), with no more than 3/8" variance between the tallest and shortest finished riser in a flight.
  • Minimum tread depth (R311.7.5.2): 10" horizontal run measured nosing-to-nosing.
  • Minimum clear width (R311.7.1): 36" above handrail height.
  • Maximum single-flight vertical rise (R311.7.3): 151" (12' 7") between floor levels or landings; taller rises require splitting into two or more flights with an intermediate landing.
  • Minimum stringer throat depth: 3 1/2" perpendicular structural wood left behind the deepest notch (5" recommended for exterior spans over 8 feet).
  • Handrails & headroom (R311.7.2 & R311.7.8): 6'-8" minimum vertical headroom clearance and a graspable handrail whenever a flight has 4 or more risers.

Limitations & what this calculator does not check: Local municipalities (including parts of California, New York, and commercial IBC stairs) may enforce stricter maximum risers (7") or deeper treads (11"). This tool does not perform structural beam deflection calculations for unsupported stringer spans over 10–12 feet, ledger-board flashing/lag-bolt sizing, or frost-depth footing design. Verify mid-span support blocking and local amendments with your building inspector before cutting.

Exact Carpentry Math Formulas Used on This Page

All fractional outputs round to the nearest 1/16" after full double-precision calculation:

Riser Count = ceil(Total Rise / 7.75)
Riser Height (R) = Total Rise / Riser Count
Tread Count = (Mount == Flush) ? Riser Count : Riser Count - 1
Stringer Diagonal = sqrt(Total Rise² + Total Run²)
Throat Depth = Actual Board Width - (R × T) / sqrt(R² + T²)
Bottom Riser Drop Cut = R - Finished Tread Thickness

For comfort checking, the classic Blondel stride rule (2R + T) targets 24" to 25". A 7 3/8" riser paired with a 10 1/2" tread produces 25.25" and a 35.1° pitch.

Why does the bottom riser of a stair stringer get cut shorter than the rest?

Every step above the ground receives a tread board on top of the stringer, shifting the whole flight upward by one tread thickness. If you do not trim one full tread thickness (for example 1 1/2" for 2x decking or 1" for interior oak) off the bottom seat cut, the first step up from the floor will be taller by that exact thickness and violate the IRC R311.7.5.1 3/8" maximum riser variation rule.

Can I cut residential stair stringers out of 2×10 lumber instead of 2×12?

Almost never for standard 7 1/2" × 10 1/2" steps. A nominal 2×10 is only 9 1/4" wide, and a 7 1/2" × 10 1/2" step notch removes 6 1/8" perpendicular to the edge—leaving just 3 1/8" of remaining throat depth, which fails the 3 1/2" minimum effective depth requirement. Switching to 2×12 (11 1/4" actual width) leaves 5 1/8" of solid structural throat.

What is the difference between a dropped mount and a flush top mount?

In a dropped (standard hanger) mount, the top cut tread sits one riser height below the finished upper floor or deck surface, so the upper landing acts as the top step and tread count equals risers minus one. In a flush mount, the top tread sits level with the upper surface, extending the landing outward by one tread so tread count equals riser count.

How many stringers do I need for a 36-inch or 48-inch wide staircase?

For solid 2×6 or interior 1" hardwood treads spaced up to 16" on center, a 36" stair typically uses 3 to 4 stringers (4 stringers keeps every clear span strictly under 16" OC) and a 48" stair uses 4 stringers. For composite deck boards, manufacturers require 12" maximum on-center spacing, which bumps a 48" stair up to 5 stringers.

When does IRC R311.7 require a continuous graspable handrail?

Under IRC R311.7.8, any residential stairway with 4 or more risers must have a continuous handrail mounted between 34" and 38" vertically above the sloped nosing line on at least one side. Open sides with a drop greater than 30" above grade also require a 36" guard.

Related Framing & Lumber Calculators